Why your furnace makes water
A high-efficiency (90%+ AFUE) condensing furnace extracts so much heat from the exhaust that water vapor condenses into liquid inside the secondary heat exchanger, often several gallons on a cold day. That water is slightly acidic. It flows through an internal trap, then out a drain line to a floor drain, the outdoors, or a condensate pump if gravity drainage isn't possible.
In many Schertz homes, the AC evaporator coil sits on top of the furnace and shares the same drain system, so drains work year-round.
Signs of a condensate problem
- Water pooling around a closet or garage furnace
- A stain or sagging spot on the ceiling under an attic furnace
- Water dripping from a pipe over a window or eave, meaning the secondary drain is working because the primary is clogged
- A pressure-switch error code: water backed up in the trap blocks the pressure port
- A gurgling sound from the furnace
- A condensate pump that runs constantly, hums without pumping, or has water in its overflow
Common causes
- Algae and slime in the drain line, especially in summer when the AC adds water. Texas heat makes this very common.
- A clogged internal trap from debris and residue
- Failed condensate pump: a stuck float, burned-out motor or clogged check valve
- Improper slope on drain lines, especially long attic runs
- Freezing in an unheated attic or garage during a hard freeze, rare in Schertz but it happened during Winter Storm Uri
- Rusted or cracked drain pan, or a missing float switch
Water coming through the ceiling? Turn the system off, put a bucket under the drip and call. If the ceiling is bulging, a small hole at the lowest point can drain it safely into a bucket. See attic furnace repair.
What the repair includes
- Clear and flush the primary drain line, and the secondary line if present.
- Remove and clean the internal trap, then refill it so it seals properly.
- Test or replace the condensate pump, including its safety switch.
- Test the float switch in the drain pan so the system shuts off before an overflow.
- Check slope and connections, and fix sags or leaks.
Preventing clogs
A yearly tune-up includes flushing the drain and testing the float switch. Between visits, some homeowners pour a cup of white vinegar into the drain access port every few months to slow algae growth. Ask your technician where the port is and whether it's appropriate for your system.
Condensate drain and pump repair cost
| Item | Typical cost | Notes |
|---|---|---|
| Drain line clearing and flush | $120 – $300 | Primary and secondary lines |
| Internal trap cleaning | $120 – $250 | Fixes many pressure-switch codes |
| Condensate pump replacement | $180 – $450 | Includes safety switch wiring |
| Float switch installation | $120 – $250 | Recommended for attic units |
| Drain pan replacement | $250 – $600 | Rusted or cracked pans |