Many homes in newer Schertz and Cibolo subdivisions don't burn gas at all. They heat with a heat pump, backed by electric resistance heat strips in the indoor air handler. Older all-electric homes may have a standalone electric furnace that works the same way.
How electric heat works
Electric heat strips are coils of resistance wire, like a giant toaster, mounted in the air handler. When they get power, they glow and heat the air the blower pushes past them. They're rated in kilowatts (commonly 5, 8, 10, 15 or 20 kW) and usually switch on in stages so they don't overload your electrical panel.
In a heat pump system, the strips act as auxiliary (AUX) heat. They turn on automatically when:
- The heat pump runs a defrost cycle to melt ice off the outdoor coil
- The house falls a few degrees below the set point and the heat pump can't catch up alone
- Outdoor temperatures drop so low that the heat pump loses efficiency, as in a hard Texas freeze
Emergency (EM) heat is different: it's a manual setting that shuts off the heat pump and runs only the strips. It's meant for when the outdoor unit has failed. Read em heat vs heat for when to use it, and why running it for weeks can shock you on your electric bill.
Signs your heat strips or electric furnace need repair
Cool air during defrost
If air from the vents turns cold for more than a few minutes during defrost, the strips may not be energizing.
Can't keep up in a freeze
The heat pump runs constantly and the house keeps getting colder: one or more strip stages may have burned out.
Tripping breaker
A shorted element, a failed relay or loose connections can trip the air handler breaker when the strips engage.
Lasting burning smell
Dust burning off the strips the first time each season is normal. A strong, persistent or electrical smell is not.
Electrical safety: heat strips run on 240 volts with high current. Don't remove air handler panels or touch the heating elements. A strong burning or melting smell means turn the system off at the thermostat and the breaker, then call.
What we test and repair
- Heating elements: resistance and amperage on each element. Broken coils are replaced.
- Sequencers and relays: the switches that bring each stage on one at a time. Failed sequencers are a very common cause of "only some heat".
- Limit switches and thermal fuses: safety devices that cut power if the strips overheat, often because of a clogged filter or a weak blower.
- Wiring and breakers: heat and loose connections can scorch terminals and wires. We tighten, repair or replace them.
- Thermostat staging: making sure AUX heat comes on when it should, and not when it shouldn't (which wastes electricity).
- Blower and airflow: electric heat needs strong airflow. Low airflow is the number one cause of tripped limits and burned elements.
Running costs: why heat strips matter in Schertz
Heat strips convert electricity to heat one-to-one. A heat pump moves heat and typically delivers two to three times more heat per unit of electricity in mild weather. That's why a system stuck on AUX or EM heat can double a winter electric bill. If your bill jumped during a normal cold spell, have the heat pump checked. The strips may be doing work the heat pump should be doing.
Electric furnace and heat strip repair cost
| Item | Typical cost | Notes |
|---|---|---|
| Heating element replacement | $200 – $600 | Per element; depends on kW rating |
| Sequencer or relay | $150 – $400 | Common cause of partial heat |
| Limit switch / thermal fuse | $150 – $350 | Often triggered by poor airflow |
| Wiring or terminal repair | $150 – $450 | Scorched connections |
| Complete heat strip kit | $500 – $1,200 | When the whole kit is failing |