Em heat vs heat: what your thermostat is telling you

If your Schertz home has a heat pump, your thermostat probably shows HEAT, AUX and EM HEAT. Knowing the difference can prevent a surprise electric bill and tell you when something's wrong.

Quick answer

HEAT runs the heat pump normally. AUX heat means the thermostat automatically added electric heat strips to help, which is normal in cold weather and during defrost. EM (emergency) heat is a manual setting that turns the heat pump off and runs only the strips. Use EM heat only when the heat pump has failed, because it costs much more to run.

The three settings, side by side

Setting What runs Turned on by Running cost
HEAT Heat pump only You (normal mode) Lowest
AUX heat Heat pump + electric heat strips The thermostat, automatically Higher, for short periods
EM heat Heat strips only; heat pump off You, manually Highest

Why heat strips cost more

A heat pump doesn't create heat. It moves heat from outdoor air into your home. In mild weather it can deliver two to three times more heat than the electricity it uses. Heat strips are electric resistance heaters that convert electricity to heat one-to-one. That's why heating with strips alone can double the cost of heating.

When AUX heat comes on (normally)

  • During defrost: the heat pump briefly reverses to melt ice off the outdoor coil, and the strips keep indoor air warm.
  • When you raise the set point several degrees: many thermostats bring on AUX to catch up faster.
  • In hard freezes: as outdoor temperatures drop, the heat pump needs help, as it did during Winter Storm Uri.

Signs something's wrong

  • AUX is on almost all the time in mild weather (40s–50s)
  • The outdoor unit isn't running when the heat is on
  • The outdoor coil stays caked with ice
  • Your electric bill jumped with no unusual cold

These point to a heat pump problem, such as low refrigerant, a failed defrost control or a bad outdoor fan, with the strips covering for it at high cost. See heating repair.

When to use EM heat

Switch to EM heat when the outdoor heat pump has clearly failed (it's not running, it's damaged, or it's iced solid) and you need heat until it's repaired. Then schedule service promptly, and switch back to HEAT once it's fixed.

Bill-saving tip for Schertz heat pump owners: avoid big thermostat setbacks. Dropping 8–10 degrees overnight and raising it in the morning often triggers AUX heat to recover quickly, which can erase the savings. Small setbacks of 2–3 degrees, or a smart thermostat with heat pump recovery settings, work better.

Heat strip problems

If AUX heat runs but the house still won't warm up, or you smell burning from the vents, the heat strips themselves may be failing. See electric furnace & heat strip repair.

FAQ

Frequently asked questions

Don't see your question? Call (210) 898-9282.

Is it bad if my thermostat says AUX heat?

No, it's normal during cold weather and defrost cycles. It's only a concern if AUX runs constantly in mild weather, which can indicate a heat pump problem.

Should I use emergency heat when it's freezing outside?

Not just because it's cold. The system adds AUX heat automatically. Use EM heat only if the outdoor heat pump has failed.

Why is my heat pump blowing cool air?

Heat pump air feels cooler than furnace air (often 90–100°F at the vent versus 120°F+). During defrost it can briefly feel cool. Persistent cool air may mean failed heat strips or a heat pump fault.