Check the thermostat (HEAT mode, set point above room temperature, batteries), the furnace breaker, the on/off switch near the furnace, and the furnace door panel. Also check for water in the drain pan, since a tripped float switch shuts the system off. If those are fine, the furnace may be in lockout or have a failed part.
The 8-step checklist
- Thermostat mode and set point. Make sure it's on HEAT (not COOL or OFF) and set 3–5 degrees above the current room temperature.
- Thermostat power. Replace the batteries if it uses them. A blank screen means no power. Smart thermostats may also show a "C-wire" or power error.
- Furnace breaker. Find the breaker labeled furnace, air handler or HVAC. If it's tripped, reset it once. If it trips again, stop and call.
- Furnace on/off switch. Usually a light switch on or near the furnace, in the closet, garage or attic. It's easy to flip off by mistake.
- Furnace door panel. A safety switch cuts power if the front panel isn't fully seated. Push it firmly into place.
- Drain pan and float switch. For attic or closet units with an AC coil on top, check the pan underneath. Water there may have tripped a float switch that shuts everything off. See furnace leaking water.
- Gas supply. Are other gas appliances working? Is the gas valve on the furnace's supply line in line with the pipe (open)?
- Lockout. After several failed ignition attempts, many furnaces lock out for about an hour. See how to reset a furnace, but reset only once.
Look at the control board light. Most furnaces have a small LED visible through a window in the lower panel. A blinking pattern tells a technician a lot. Count the flashes before you call. See blinking light codes.
If the checks don't help
When power, thermostat and switches are all fine, the problem is usually inside the furnace:
Blown control fuse
A 3A or 5A fuse on the board, often blown by a shorted thermostat wire. See control board.
Failed transformer
No 24-volt power means the thermostat can't signal the furnace.
Inducer or pressure switch
The furnace starts, then stops before ignition. See pressure switch.
Igniter
Clicking but no flame. See igniter replacement.
Common in Schertz: the first cold night
The most furnace-won't-start calls come the first time the heat runs each season, usually with the first strong cold front in November or December. Parts that sat idle all summer, especially igniters, fail on that first start. A fall tune-up is the best prevention.
Smell gas or burning? Skip the checklist. Turn nothing on, leave the home if you smell gas, and call 911 or your gas utility from outside.